Knowledge Base, Manuals & Downloads

00380 / 00381 Thermometer

00380 AcuRite Thermometer

Manual Digital Thermometer Instruction Manual 00380 / 00381 [PDF]
Français: Guide d'instructions 00380W / 00381 [PDF]
Replacement Parts Replacement Sensor: 606TX


Display Dimensions: 3-inches Height x 2.5-inches Width x 1.3-inches Depth
Indoor Temperature Range:
 32º to 122º F, 0º C to 50º C

Temperature Accuracy: +/- 2 degrees Fahrenheit; Learn more
Power: 2 AAA alkaline batteries


Outdoor Temperature Range: -40º to 158º F, -40º C to 70º C
Temperature Accuracy: +/- 2 degrees Fahrenheit; Learn more
RF (wireless) Range: 165' (50m)
Wireless Frequency: 433 MHz
Data Reporting: 30 second updates
Power: 2 AA alkaline or lithium* batteries
*Lithium batteries recommended for temperatures below -4 degrees Fahrenheit / -20 degrees Celsius

Problem Possible Solution
is flashing or
showing dashes

Flashing of the outdoor temperature is generally an indication of wireless interference.
1. Bring both the sensor and display unit indoors and remove at least one battery from each.
2. Reinstall the battery in the outdoor sensor.

3. Reinstall the battery in the display unit.
4. Let the units sit within a couple feet of each other for about 20 minutes to gain a strong connection.

Select degrees
Fahrenheit or Celsius

To select between degrees Fahrenheit (ºF) or Celsius (ºC) temperature units, press the ºC/ºF button located inside the battery compartment of the display.

No outdoor 

If the wireless signal indicator shows no bars:
• Relocate the display unit and/or the outdoor sensor. The units must be within 165 ft (50 m) of each other.
• Make sure both units are placed at least 3 feet (.9 m) away from electronics that may interfere with the wireless communication (such as TVs, microwaves, computers, etc).  
• Use standard alkaline batteries (or lithium batteries in sensor when temperature is below -4ºF/-20ºC). Do not use heavy duty or rechargeable batteries. NOTE: It may take up to 20 minutes for display unit and sensor to synchronize after batteries are replaced.
Make sure both the display unit and sensor are placed out of direct sunlight and away from any heat sources or vents.
Display screen
not working
Check that the batteries are installed correctly. Batteries may need to be replaced.
Hi / low records High/low records automatically clear every 24 hours. The time records are cleared is determined by the time the battery was installed. For example, if battery was installed at 6:00 pm, then high/low records reset at 6:00 pm daily.


Questions? We're here to help.

Phone +1 877 221-1252  |  AcuLink Technical Support +1 844 228-5465 |  Email:  |  Community forum:

Models: 00380, 00380W, 00380W1, 00381




install the AcuRite 5-in-1 weather sensorInstall the 5-in-1 Weather Sensor

Step-by-step directions with video to set up your 5-in-1 weather sensor for maximum accuracy.

install the AcuRite 3-in-1 weather sensorInstall the 3-in-1 Weather Sensor

Step-by-step directions with video to set up your 3-in-1 weather sensor for maximum accuracy.

maximize wireless range troubleshootingGet the Best Wireless Range

Maximize the wireless range of AcuRite's 433 MHz wireless technology for superior performance.

how to site a weather sensorSensor Siting to Maximize Accuracy

Sensor siting helps install your sensors in the way that best captures the data that is most important to you.

acurite battery requirementsBattery Requirements for AcuRite Products

AcuRite recommends new, high quality, name brand alkaline batteries for the best product performance.